Flammable Dusts, Vapours, Gases
and Hybrid fuels

TestSafe provides a dust explosion testing service to the full ISO 6184 Parts 1,2 and 3 standard. TestSafe has both the ISO6184 1000 litre reference dust explosion chamber, and a 20-litre chamber. New Dust Explosion Test Instrument Developed In-House, please click here for more details.

Testing includes: -

Minimum Explosive Concentration (MEC)
Lower Explosive Limit (LEL)

The minimum dust cloud concentration (MEC) or gas or vapour (LEL) in air below which the dust or fuel is unlikely to explode.

Limiting Oxygen Concentration (LOC)

The oxygen concentration in air below which the dust cloud or fuel may become inert.

Pmax

The maximum pressure, usually expressed in bar (gauge), found when tested over a range of dust cloud concentrations.

Kst or Kg

The normalised maximum rate of pressure rise, usually expressed in bar.m/sec, found when tested over a range of dust cloud or fuel concentrations.

TestSafe can undertake research tests involving explosion suppression and explosion venting.



Tell me more about testing and assessment of electrical equipment for hazardous areas.



Tell me more about TestSafe's Fire & Explosion and Electrical testing capabilities.



We will also consider undertaking test requirements to other standards or similar tests as required. Should you require any further information, please use the enquiry form.